There are various  steps in the water purification process and  though it might seem like one would desire a physics degree to recognise, this guide should assist to simplify the entire process of water refinement.

The 1st step in water refinement includes the water being transported to and getting unloaded at the facility. All incoming loads of water are tested for Chloride (NaCl) and percentage of solids before unloading is allowed. Once all tests are done, the water can then be separated for distribution within the plant. Not all fluids will be sent to exactly the same place. Fluids containing high solid levels are sent directly to the dewater process, as all other fluids are sent to the inlet pits for commingling.

The water is then moved into the mix tanks, that are made to let for the commingling and circulation, through means of pneumatic and/or propelled agitation, of all incoming fluids as wells as the natural separation of heavy solids (fallout) and oil (precipitation). The tanks are separated into a high-solids and low-solids system made to control all incoming fluids at the systems entrance.

The 3rd stage in the procedure consists of going through a multi-stage tank battery system and de-watering. Initial, the fluids traverse via the tank battery system called the rifle barrel, that's a chambered storage vessel with an adjustable skimming plate designed to capture oil as it separates from the fluids. All oil captured is sent to the "crude oil sales" tank and remaining effluent fluids from the gun barrel are sent to the 2nd stage of storage, 2 large holding tanks which allow for adequate system volume capacities. That 2nd stage is called de-watering, that's where all of the heavy solids captured in the system transfer to, and introduced to heavy molecular weight polymers and co-polymers.

Any fluid leftover after stage three of the operation are sent to the solid separator units where a number of improvements also as injections are made and the remaining effluent fluids of the solids separation units are subjected to a number of quality control tests prior to clearance to the next stage of the procedure is allowed. Any levels indicated above performing standards will desire instant re-processing.

The fifth and final stage called micron and multi-media filtration consists of all fluids from step 4 are sent through a series micron and multi-media filtration units in respective order given that the fluid passed all needs .